Version 3.14.0.9 (Released: 2021/11/22)

  • (NEW FEATURE) Ability to customize Axiom GPS synchronization interval [DL-2495]
  • (IMPROVEMENT) Automatic reboot of non-responsive G6 GOES transmitter [DL-2536]

Version 3.13.0.1 (Released: 2021/02/17)

  • (IMPROVEMENT) Updated Tables for Calculating Antenna Declination [DL-2521]

Version 3.12.0.16 (Released: 2019/08/13)

  • (BUG FIX) Dataloggers with specific Ubicom telemetry setup failed to restart after upgrade to AS ver 3.12.0.14 [DL-2479]

Version 3.12.0.14 (Released: 2019/07/16) [RECALLED 2019/08/09]

  • (NEW FEATURE) Ubicom Telemetry Data Transmission Timing Window DL-2476
  • Bubbler Extension Changes:]
    • (NEW FEATURE) Health Data Point Added [DL-2442]
    • (IMPROVEMENT) Purge If Greater Than Feature Removed [DL-2376]
    • (BUG FIX) Sensor Extension was not updating the Bubbler time to be synchronized with the Datalogger [DL- 2458]

    Version 3.11.0.14 (Released: 2018/02/02)

    • (NEW FEATURE) New Sensor Extension for the SDI-THS-3 Temperature and Humidity Sensor [DL-2271]
    • (IMPROVEMENT) Switch Dual Ubicom between Iridium and Cell from the Status Screen [DL-2375]
    • (BUG FIX) Stage Sensor Burst Averaging output error [DL-2404]
    • (BUG FIX) Revert changes made to data store time [DL-2433]

    Version 3.11.0.13 (Released: 2017/09/19, Recalled 2018/01/26)

    • (NEW FEATURE) New Sensor Extension for the SDI-THS-3 Temperature and Humidity Sensor [DL-2271]
    • (IMPROVEMENT) Switch Dual Ubicom between Iridium and Cell from the Status Screen [DL-2375]
    • (BUG FIX) Stage Sensor Burst Averaging output error [DL-2404]

    Version 3.8.0.57 (Released: 2017/08/10)

    • (NEW FEATURE) New Sensor Extension for FTS Bubbler [DL-2310]
    • (BUG FIX) G6 Quick Deploy variants default power settings [DL-2224]
    • (BUG FIX) Pseudo Binary GOES message format allowed non-printable characters [DL-2342]

    Version 3.7.4.3 (Released: 2017/06/14)

    • (NEW FEATURE) New telemetry type – Ubicom DoD [DL-2387]

    Version 3.7.3.22 (Released: 2016/09/29)

    • (NEW FEATURE) FTS Bluetooth Telemetry Device [ZOOM-1]
    • (NEW FEATURE) Telemetry Status Indicators for WRLS-AXIOM-PC Telemetry [ZOOM-9, ZOOM-10]

    Version 3.7.2.8 (Released: 2016/03/09)

    • (NEW FEATURE) Conditional SDI Measurements for SDI Sensors [DL-2317]
    • (BUG FIX) Multiple command strings of the same name used by Generic SDI Sensors can now be viewed [DL-2318]

    Version 3.7.1.3 (Released: 2016/02/19)

    • (NEW FEATURE) AirTalk Vocabulary [DL-2308]
    • (BUG FIX) Occasional continuous Datalogger restarts when using AirTalk telemetry [DL-2313]

    Version 3.7.0.13 (Released: 2016/02/03)

    • (BUG FIX) Minimum and Maximum value limits from one form being transferred to different forms [DL-2205]
    • (BUG FIX) Datalogger applying an aged default time value if invalid Ubicom Date/Time received [DL-2297]
    • Discharge Process related changes:
      • (IMPROVEMENT) Stage input selector in alphabetical order [DL-2240]
      • (IMPROVEMENT) Stage Discharge process can be saved without a table [DL-2241]
      • (IMPROVEMENT) Stage Discharge files time stamped [DL-2242]
      • (IMPROVEMENT) Format and Under Range fields added to the Discharge Configuration screen [DL-2253, DL-2266]
      • (IMPROVEMENT) Discharge Process screen displays Shift [DL-2255]
      • (BUG FIX) Discharge calculation corrected [DL-2244]
      • (BUG FIX) Erroneous shifts reported for out of bounds stage values [DL-2246]

    Version 3.5.2.2 (Released: 2016/01/21)

    • (BUG FIX) Declination Error in Audit Log [DL-2298]

    Version 3.5.1.1 (Released: 2015/12/07)

    • (IMPROVEMENT) Start Visit Report feature – Time Since Last Visit [DL-647]
    • (IMPROVEMENT) Added running Delta to the list of Average Process output [DL-1082]
    • (IMPROVEMENT) New information included on Site Visit Reports [DL-1327]
    • (IMPROVEMENT) Visit Reports include sensor information [DL-1364,DL-2249]
    • (IMPROVEMENT) Notes section of Site Visit Reports delineated [DL-2152]
    • (BUG FIX) Start Visit Report technician name accepts numerals [DL-482]
    • (BUG FIX) Visit Report – detected SDI-12 Sensors are printed on the visit report [DL-1353]
    • (BUG FIX) Site Visit Report – GOES window length logged [DL-2087]
    • (BUG FIX) Valid GPS fix intervals modified to prevent audit log error and Datalogger transmit failure [DL-2119]
    • (BUG FIX) Unexplained reboot while loading large configuration file [DL-2192]
    • (BUG FIX) Failure to download data if reserved characters used [DL-2220]
    • (BUG FIX) Discharge Output calculated from a Discharge Process available as a data point [DL-2254]
    • (BUG FIX) Cannot download selected data due to a single bad variable [DL-2272]
    • (BUG FIX) Placeholder columns in CSV export [DL-2276]
    • (BUG FIX) Ubicom time synchronization not occurring on the interval consistently [DL-2284]
    • (BUG FIX) Large blocks of missing data when using Ubicom [DL-2285]

    Version 3.4.1.4 (Released: 2015/09/30)

    • (NEW FEATURE) MODBUS – Additional time registers added [DL-2228]
    • (BUG FIX) MODBUS – Latest data not returned [DL-2226,DL-2090]

    Version 3.4.0.18 (Released: 2015/09/24)

    • (NEW FEATURE) Radar Stage Sensor Extension [DL-2186]
    • (NEW FEATURE) Stage-discharge rating table to convert stage to flow [DL-1998]
    • (BUG FIX) Datalogger with G6 Port does not support pre-existing G5 configurations correctly [DL-2216]
    • (BUG FIX) Cannot set the GOES Configuration from Panorama [DL-2218]

    Version 3.3.2.34 (Released: 2015/09/11)

    • (IMPROVEMENT) Auto-fill Measurement Time feature for automatically assigning offset timing when adding SDI-12 sensors [DL-2009]
    • (IMPROVEMENT) Audit Log Entries reduced for DigiTemp [DL-2072]
    • (IMPROVEMENT) G5 GOES test transmission default channel [DL-2083]
    • (IMPROVEMENT) Data Download: Date Range and Data Set selections remain persistent [DL-2141, DL-2150]
    • (IMPROVEMENT) Clock appears while the End Visit Report is being written to the USB [DL-2145]
    • (IMPROVEMENT) Telemetry Self-Timed Message screen colours reverted to white text on blue [DL-2191]
    • (BUG FIX) Axiom GOES Tx window set with leading zeroes displays the wrong error dialog and fails to send GOES transmissions [DL-2086]
    • (BUG FIX) Higher numbered AS versions were not being recognized as a newer release [DL-2105]
    • (BUG FIX) Disconnected SDI-UWS-Gill failed to report a blank field for an Average Process (minimum wind speed) [DL-2133,DL-2134]
    • (BUG FIX) Random Transmission Conditions screen now indicates the interval time [DL-2144]
    • (BUG FIX) Order of Processes was not reflected in the Configuration File [DL-2147]
    • (BUG FIX) Downloaded Data precision was not correct when using Selected variables for the Data Set [DL-2149]
    • (BUG FIX) G5 CS1 Power Levels are read only [DL-2172]
    • (BUG FIX) Stage field offset not displayed when configuration file reloaded [DL-2207]
    • (BUG FIX) Loading and invalid GPS sync source configuration file results in an AS reboot cycle [DL-2213]
    • UBICOM FEATURES
      • (IMPROVEMENT) Ubicom AT commands sent during Datalogger wait periods [DL-2189]
      • (IMPROVEMENT) Increased compatibility for Ubicom operating FW 3.2.5 or later [DL-2188, DL-2190]
      • (BUG FIX) Datalogger and Ubicom failing to communicate after routine scheduled power downs of Ubicom or Ubicom attempts to wake up the Datalogger [DL-2206, DL-2209]

    Version 3.3.0.45 (Released: 2015/07/10)

    • (NEW FEATURE) G6 Transmitter Operates with GOES, Meteosat, and International Satellite Systems
    • (NEW FEATURE) New drop down menu to select Ubicom telemetry
    • (NEW FEATURE) Ubicom status screen
    • (NEW FEATURE) Ability to download the Ubicom audit Log
    • (NEW FEATURE) Ability to communicate directly with the Ubicom in transparent mode
    • (NEW FEATURE) Ubicom status information included in the Visit Report
    • (NEW FEATURE) Ability to generate a timed or conditional message via Ubicom
    • (NEW FEATURE) GPS synchronization and position reporting of the Datalogger using Ubicom
    • (BUG FIX) Several failed calls for Dataloggers operating with GlobalStar modems over GSNet

    Version 3.2.1.12 (Released: 2015/06/02)

    • (IMPROVEMENT) Add comments to Start and End Visit Reports [DL-1949,DL-2058]
    • (IMPROVEMENT) Ability to order Processes[DL-1954]
    • (IMPROVEMENT) Ability to only download the data since the last visit [DL-1995]
    • (IMPROVEMENT) Ability to specify missing data number on export files [DL-2011]
    • (IMPROVEMENT) Ability to maintain CSV data download field orders [DL-2050]
    • (IMPROVEMENT) Windsonic sensor extension added kph in units menu [DL-2063]
    • (IMPROVEMENT) Empty In-line logging intervals automatically deleted without deleting the sensor [DL-2080]
    • (BUG FIX) Windsonic sensor extension did not recognize all Gill Windsonic sensors [DL-2061]
    • (BUG FIX) Unable to change In-line Logging Interval for SDI Sensors which use multiple commands [DL-2091]
    • (BUG FIX) In-line Logging imported even though sensor not supported by the Datalogger [DL-2122]
    • (BUG FIX) FTS Get Telem Configuration fails to return GOES interval correctly [DL-2126]

    Version 3.2.0.35 (Released: 2015/05/08)

    • (BUG FIX) Potential datalogger crash and corruption of the data store if power is lost during a data read or write [DL-1972,DL-2017,DL-2019]
    • (BUG FIX) Potential data corruption from updating configuration while logging frequently [DL-2106,DL-2107]
    • (BUG FIX) Potential data corruption when logging to a previous point in time [DL-2110,DL-2111]

    Version 3.1.11.9 (Released: 2015/04/07)

    • (BUG FIX) Tavis Sensor Extension returned error (“err”) for the HG-Raw value
    • (BUG FIX) Some SDI sensors did not display a full list of data points
    • (BUG FIX) Unable to set the Stage Offset Datapoint in Stage Sensor via StreamTrac
    • (BUG FIX) Audit log not making an entry when a data point value has been altered
    • (BUG FIX) RVT “Logger not responding” message occurring with AS versions 3.1.7.26 and 3.1.6.24
    • (BUG FIX) Current conditions did not report negative numbers
    • (BUG FIX) Sensor data points were not showing without a restart, when in-line logging was skipped

    Version 3.1.9.3 (Released: 2015/03/13)

    • (BUG FIX) SR50 Snow Sensor Extension – Old value being logged after a sensor read is completed.

    Version 3.1.8.1 (Released: 2015/02/27) CUSTOM RELEASE: FOR MEXICAN EMAS WEATHER STATIONS

    • (IMPROVEMENT) RMY-85000 Ultrasonic Sensor Lockup Detected and Rectified

    Version 3.1.7.26 (Released: 2015/02/25)

    • (IMPROVEMENT) In-Line Logging permits defining “Logging Intervals” and “Current Conditions” data points directly from the “Sensor Setup” screen
    • (BUG FIX) Services Page not loading
    • (BUG FIX) Data transferred to USB stick and data transmitted via pseudo binary used different rounding conventions
    • (BUG FIX) “Get Datalogger Details” command did not contain station description

    Version 3.1.6.4 (Released: 2015/02/12)

    • (NEW FEATURE) New USGS compatible Pseudo Binary transmission data format
    • (NEW FEATURE) Random Transmission in WSC format
    • (NEW FEATURE) Datalogger supports new telemetry type (Ubicom)
    • (IMPROVEMENT) Two new FTS commands for use with Ubicom Telemetry
    • (IMPROVEMENT) Ubicom telemetry permits data request by fields
    • (IMPROVEMENT) Ubicom telemetry permits selecting a portion of the audit log
    • (BUG FIX) Changing/Loading a configuration file did not change the ConfigID
    • (BUG FIX) Tsampler Process – Threshold units incorrect
    • (BUG FIX) Configuration uploads via Ubicom using Panorama 3.1 cause corruption
    • (BUG FIX) User Interface not sleeping on timeouts and excessive amount of requests being sent to the G5

    Version 3.1.5.9 (Released: 2014/12/05)

    • (New Feature) Sensor Extension for Gill Ultrasonic Wind Sensor
    • (New Feature) Sensor Extension for CampBell SR50A Sonic Ranging Sensor (Snow Depth)
    • (Bug Fix) Rain sensor output now returns the set precision value [DL1535]
    • (Bug Fix) Delete Logging Intervals button now fully visible [DL1994]

    Version 3.1.2.11 patch (Released: 2014/09/18)

    • (Enhancement) Now supports Axiom models H1-R, H1-S, H1-RS
    • (Bug Fix) Prevents an “out of memory” condition from occuring

    Version 3.1.1.165 (Released: 2014/09/05)

    • (New Feature) Ability to access G5 transmitter through transparent mode [DL1436]
    • (Enhancement) Improved naming of Threshold Sampling process data points [DL715]
    • (Enhancement) TTS threshold values can now be edited in touchscreen interface [DL456]
    • (Enhancement) Option to not use “-99999” for blank data points [DL1594]
    • (Enhancement) Variable polling duration can now be entered for setting stage offset [DL1686]
    • (Enhancement) Axiom will push configured units to sensor when sensor’s stored units conflict with those configured [DL1705]
    • (Enhancement) Order of variables for Current Conditions output can be now set [DL1763]
    • (Enhancement) Telemetry screen now defaults to Telemetry A tab [DL1802]
    • (Enhancement) Full OS version now displayed in Station Setup [DL1815]
    • (Enhancement) Wake-up delay now user-adjustable [DL1839]
    • (Enhancement) Both raw and offset values now included when using polling feature to set stage offset [DL1915]
    • (Enhancement) Ability to force SDI sensor reading measurement for real-time Current Conditions [DL1918]
    • (Bug Fix) “Not enough disk space” error could occur during update of application software [DL1587]
    • (Bug Fix) Changes to data point names would not carry through to scripts which contained the data points in their name [DL1666]
    • (Bug Fix) RVT power would be cut when entering Telemetry Status screen [DL1712]
    • (Bug Fix) Datalogger crash when inadvertently removing USB memory stick before software update completed [DL1725]
    • (Bug Fix) Minimum/Maximum values at time of occurrence not being logged [DL1740]
    • (Bug Fix) Incorrect logging of Depth Integrated sample and Auxiliary sample prior to Threshold sample taken [DL1412]
    • (Bug Fix) Duration of SDI sensor mapping could be unreasonably long [DL1756]
    • (Bug Fix) Crash when deleting variables from WSC message screen [DL1766]
    • (Bug Fix) Crash when defining a Depth Integrated or Auxiliary sample in the TSampler process [DL1785]
    • (Bug Fix) Weighted Average process would not recover from an error input [DL1812]
    • (Bug Fix) GPS position not recorded regularly, preventing use in calculations [DL1931]
    • (Bug Fix) Incorrect “missing values” placeholder in pseudobinary messages [DL1910]

    Version 3.0.0.71 (2014/03/25)

    • (Enhancement) Option to replace data gaps with ‘-99999’ during CSV download [DL1594]
    • (Enhancement) SDI ports now can use configurable delay to support older SDI sensors [DL1871]

    Version 3.0.0.59 (2014/02/14)

    • (Bug Fix) Random pseudo binary or time-ordered transmissions would occur even when conditions not met [DL1889]
    • (Bug Fix) Behaviour of Change since last logged value corrected to match description on Setup screen [DL1898]
    • (Enhancement) Behaviour of Redundant Data option changed to include data from previous transmissions [DL1890]

    Version 3.0.0.57 (2013/09/06)

    • (Bug Fix) Cumulative Rainfall (RNIN) improperly reset [DL1669, DL1670]
    • (Bug Fix) Low Memory caused a logger reboot [DL1768]
    • (Bug Fix) Error while deleting Transmission parameters [DL1826]
    • (Bug Fix) SDI Command Setup UI Issue [DL1840]

    Version 3.00.49 patch (2013/05/29)

    • (Bug) SDI port remains locked for sensors that don’t issue break sequence after M command [DL1783]

    Version 3.00 (2013/03/26)

    • (New Feature) New icon set makes the Axiom more intuitive, easier to learn and international [DL1434]
    • (New Feature) New Running Peak Calculation Process for Wind Speed [DL1573]
    • (New Feature) Ability to include redundant data in pseudo-binary transmission [DL1650]
    • (Enhancement) Sensor setup added for DigiTemp [DL1218]
    • (Enhancement) Backup con!guration prevents endless power cycle loop [DL1622]
    • (Enhancement) Screen reorganization to Turbidity Threshold Sampling (TSampler) process [DL1661]
    • (Enhancement) Button added to Station Setup screen to clear configuration [DL1662]
    • (Bug Fix) Datalogger crash when editing an AirTalk message that uses a phrase that has been deleted [DL1520]
    • (Bug Fix) Datalogger crash when configuring pseudobinary random message [DL1570]
    • (Bug Fix) Stage offset value for SDI-PT sensor is lost after power cycle of datalogger [DL1665]
    • (IMPROVEMENT) Updated Tables for Calculating Antenna Declination [DL- 2521]

    • (BUG FIX) Dataloggers which are configured with Ubicom telemetry but have no push messages set up, fail to restart after upgrade to v.3.12.0.14. [DL- 2479]

    Version 3.12.0.14 (Released: 2019/07/16) [RECALLED 2019/08/09]

    • (NEW FEATURE) Ubicom Telemetry Data Transmission Timing Window DL-2476
    • Bubbler Extension Changes:]
      • (NEW FEATURE) Health Data Point Added [DL-2442]
      • (IMPROVEMENT) Purge If Greater Than Feature Removed [DL-2376]
      • (BUG FIX) Sensor Extension was not updating the Bubbler time to be synchronized with the Datalogger [DL- 2458]

    Version 3.11.0.14 (Released: 2018/02/02)

    • (NEW FEATURE) New Sensor Extension for the SDI-THS-3 Temperature and Humidity Sensor [DL-2271]
    • (IMPROVEMENT) Switch Dual Ubicom between Iridium and Cell from the Status Screen [DL-2375]
    • (BUG FIX) Stage Sensor Burst Averaging output error [DL-2404]
    • (BUG FIX) Revert changes made to data store time [DL-2433]

    Version 3.11.0.13 (Released: 2017/09/19, Recalled 2018/01/26)

    • (NEW FEATURE) New Sensor Extension for the SDI-THS-3 Temperature and Humidity Sensor [DL-2271]
    • (IMPROVEMENT) Switch Dual Ubicom between Iridium and Cell from the Status Screen [DL-2375]
    • (BUG FIX) Stage Sensor Burst Averaging output error [DL-2404]

    Version 3.8.0.57 (Released: 2017/08/10)

    • (NEW FEATURE) New Sensor Extension for FTS Bubbler [DL-2310]
    • (BUG FIX) G6 Quick Deploy variants default power settings [DL-2224]
    • (BUG FIX) Pseudo Binary GOES message format allowed non-printable characters [DL-2342]

    Version 3.7.4.3 (Released: 2017/06/14)

    • (NEW FEATURE) New telemetry type – Ubicom DoD [DL-2387]

    Version 3.7.3.22 (Released: 2016/09/29)

    • (NEW FEATURE) FTS Bluetooth Telemetry Device [ZOOM-1]
    • (NEW FEATURE) Telemetry Status Indicators for WRLS-AXIOM-PC Telemetry [ZOOM-9, ZOOM-10]

    Version 3.7.2.8 (Released: 2016/03/09)

    • (NEW FEATURE) Conditional SDI Measurements for SDI Sensors [DL-2317]
    • (BUG FIX) Multiple command strings of the same name used by Generic SDI Sensors can now be viewed [DL-2318]

    Version 3.7.1.3 (Released: 2016/02/19)

    • (NEW FEATURE) AirTalk Vocabulary [DL-2308]
    • (BUG FIX) Occasional continuous Datalogger restarts when using AirTalk telemetry [DL-2313]

    Version 3.7.0.13 (Released: 2016/02/03)

    • (BUG FIX) Minimum and Maximum value limits from one form being transferred to different forms [DL-2205]
    • (BUG FIX) Datalogger applying an aged default time value if invalid Ubicom Date/Time received [DL-2297]
    • Discharge Process related changes:
      • (IMPROVEMENT) Stage input selector in alphabetical order [DL-2240]
      • (IMPROVEMENT) Stage Discharge process can be saved without a table [DL-2241]
      • (IMPROVEMENT) Stage Discharge files time stamped [DL-2242]
      • (IMPROVEMENT) Format and Under Range fields added to the Discharge Configuration screen [DL-2253, DL-2266]
      • (IMPROVEMENT) Discharge Process screen displays Shift [DL-2255]
      • (BUG FIX) Discharge calculation corrected [DL-2244]
      • (BUG FIX) Erroneous shifts reported for out of bounds stage values [DL-2246]

    Version 3.5.2.2 (Released: 2016/01/21)

    • (BUG FIX) Declination Error in Audit Log [DL-2298]

    Version 3.5.1.1 (Released: 2015/12/07)

    • (IMPROVEMENT) Start Visit Report feature – Time Since Last Visit [DL-647]
    • (IMPROVEMENT) Added running Delta to the list of Average Process output [DL-1082]
    • (IMPROVEMENT) New information included on Site Visit Reports [DL-1327]
    • (IMPROVEMENT) Visit Reports include sensor information [DL-1364,DL-2249]
    • (IMPROVEMENT) Notes section of Site Visit Reports delineated [DL-2152]
    • (BUG FIX) Start Visit Report technician name accepts numerals [DL-482]
    • (BUG FIX) Visit Report – detected SDI-12 Sensors are printed on the visit report [DL-1353]
    • (BUG FIX) Site Visit Report – GOES window length logged [DL-2087]
    • (BUG FIX) Valid GPS fix intervals modified to prevent audit log error and Datalogger transmit failure [DL-2119]
    • (BUG FIX) Unexplained reboot while loading large configuration file [DL-2192]
    • (BUG FIX) Failure to download data if reserved characters used [DL-2220]
    • (BUG FIX) Discharge Output calculated from a Discharge Process available as a data point [DL-2254]
    • (BUG FIX) Cannot download selected data due to a single bad variable [DL-2272]
    • (BUG FIX) Placeholder columns in CSV export [DL-2276]
    • (BUG FIX) Ubicom time synchronization not occurring on the interval consistently [DL-2284]
    • (BUG FIX) Large blocks of missing data when using Ubicom [DL-2285]

    Version 3.4.1.4 (Released: 2015/09/30)

    • (NEW FEATURE) MODBUS – Additional time registers added [DL-2228]
    • (BUG FIX) MODBUS – Latest data not returned [DL-2226,DL-2090]

    Version 3.4.0.18 (Released: 2015/09/24)

    • (NEW FEATURE) Radar Stage Sensor Extension [DL-2186]
    • (NEW FEATURE) Stage-discharge rating table to convert stage to flow [DL-1998]
    • (BUG FIX) Datalogger with G6 Port does not support pre-existing G5 configurations correctly [DL-2216]
    • (BUG FIX) Cannot set the GOES Configuration from Panorama [DL-2218]

    Version 3.3.2.34 (Released: 2015/09/11)

    • (IMPROVEMENT) Auto-fill Measurement Time feature for automatically assigning offset timing when adding SDI-12 sensors [DL-2009]
    • (IMPROVEMENT) Audit Log Entries reduced for DigiTemp [DL-2072]
    • (IMPROVEMENT) G5 GOES test transmission default channel [DL-2083]
    • (IMPROVEMENT) Data Download: Date Range and Data Set selections remain persistent [DL-2141, DL-2150]
    • (IMPROVEMENT) Clock appears while the End Visit Report is being written to the USB [DL-2145]
    • (IMPROVEMENT) Telemetry Self-Timed Message screen colours reverted to white text on blue [DL-2191]
    • (BUG FIX) Axiom GOES Tx window set with leading zeroes displays the wrong error dialog and fails to send GOES transmissions [DL-2086]
    • (BUG FIX) Higher numbered AS versions were not being recognized as a newer release [DL-2105]
    • (BUG FIX) Disconnected SDI-UWS-Gill failed to report a blank field for an Average Process (minimum wind speed) [DL-2133,DL-2134]
    • (BUG FIX) Random Transmission Conditions screen now indicates the interval time [DL-2144]
    • (BUG FIX) Order of Processes was not reflected in the Configuration File [DL-2147]
    • (BUG FIX) Downloaded Data precision was not correct when using Selected variables for the Data Set [DL-2149]
    • (BUG FIX) G5 CS1 Power Levels are read only [DL-2172]
    • (BUG FIX) Stage field offset not displayed when configuration file reloaded [DL-2207]
    • (BUG FIX) Loading and invalid GPS sync source configuration file results in an AS reboot cycle [DL-2213]
    • UBICOM FEATURES
      • (IMPROVEMENT) Ubicom AT commands sent during Datalogger wait periods [DL-2189]
      • (IMPROVEMENT) Increased compatibility for Ubicom operating FW 3.2.5 or later [DL-2188, DL-2190]
      • (BUG FIX) Datalogger and Ubicom failing to communicate after routine scheduled power downs of Ubicom or Ubicom attempts to wake up the Datalogger [DL-2206, DL-2209]

    Version 3.3.0.45 (Released: 2015/07/10)

    • (NEW FEATURE) G6 Transmitter Operates with GOES, Meteosat, and International Satellite Systems
    • (NEW FEATURE) New drop down menu to select Ubicom telemetry
    • (NEW FEATURE) Ubicom status screen
    • (NEW FEATURE) Ability to download the Ubicom audit Log
    • (NEW FEATURE) Ability to communicate directly with the Ubicom in transparent mode
    • (NEW FEATURE) Ubicom status information included in the Visit Report
    • (NEW FEATURE) Ability to generate a timed or conditional message via Ubicom
    • (NEW FEATURE) GPS synchronization and position reporting of the Datalogger using Ubicom
    • (BUG FIX) Several failed calls for Dataloggers operating with GlobalStar modems over GSNet

    Version 3.2.1.12 (Released: 2015/06/02)

    • (IMPROVEMENT) Add comments to Start and End Visit Reports [DL-1949,DL-2058]
    • (IMPROVEMENT) Ability to order Processes[DL-1954]
    • (IMPROVEMENT) Ability to only download the data since the last visit [DL-1995]
    • (IMPROVEMENT) Ability to specify missing data number on export files [DL-2011]
    • (IMPROVEMENT) Ability to maintain CSV data download field orders [DL-2050]
    • (IMPROVEMENT) Windsonic sensor extension added kph in units menu [DL-2063]
    • (IMPROVEMENT) Empty In-line logging intervals automatically deleted without deleting the sensor [DL-2080]
    • (BUG FIX) Windsonic sensor extension did not recognize all Gill Windsonic sensors [DL-2061]
    • (BUG FIX) Unable to change In-line Logging Interval for SDI Sensors which use multiple commands [DL-2091]
    • (BUG FIX) In-line Logging imported even though sensor not supported by the Datalogger [DL-2122]
    • (BUG FIX) FTS Get Telem Configuration fails to return GOES interval correctly [DL-2126]

    Version 3.2.0.35 (Released: 2015/05/08)

    • (BUG FIX) Potential datalogger crash and corruption of the data store if power is lost during a data read or write [DL-1972,DL-2017,DL-2019]
    • (BUG FIX) Potential data corruption from updating configuration while logging frequently [DL-2106,DL-2107]
    • (BUG FIX) Potential data corruption when logging to a previous point in time [DL-2110,DL-2111]

    Version 3.1.11.9 (Released: 2015/04/07)

    • (BUG FIX) Tavis Sensor Extension returned error (“err”) for the HG-Raw value
    • (BUG FIX) Some SDI sensors did not display a full list of data points
    • (BUG FIX) Unable to set the Stage Offset Datapoint in Stage Sensor via StreamTrac
    • (BUG FIX) Audit log not making an entry when a data point value has been altered
    • (BUG FIX) RVT “Logger not responding” message occurring with AS versions 3.1.7.26 and 3.1.6.24
    • (BUG FIX) Current conditions did not report negative numbers
    • (BUG FIX) Sensor data points were not showing without a restart, when in-line logging was skipped

    Version 3.1.9.3 (Released: 2015/03/13)

    • (BUG FIX) SR50 Snow Sensor Extension – Old value being logged after a sensor read is completed.

    Version 3.1.8.1 (Released: 2015/02/27) CUSTOM RELEASE: FOR MEXICAN EMAS WEATHER STATIONS

    • (IMPROVEMENT) RMY-85000 Ultrasonic Sensor Lockup Detected and Rectified

    Version 3.1.7.26 (Released: 2015/02/25)

    • (IMPROVEMENT) In-Line Logging permits defining “Logging Intervals” and “Current Conditions” data points directly from the “Sensor Setup” screen
    • (BUG FIX) Services Page not loading
    • (BUG FIX) Data transferred to USB stick and data transmitted via pseudo binary used different rounding conventions
    • (BUG FIX) “Get Datalogger Details” command did not contain station description

    Version 3.1.6.4 (Released: 2015/02/12)

    • (NEW FEATURE) New USGS compatible Pseudo Binary transmission data format
    • (NEW FEATURE) Random Transmission in WSC format
    • (NEW FEATURE) Datalogger supports new telemetry type (Ubicom)
    • (IMPROVEMENT) Two new FTS commands for use with Ubicom Telemetry
    • (IMPROVEMENT) Ubicom telemetry permits data request by fields
    • (IMPROVEMENT) Ubicom telemetry permits selecting a portion of the audit log
    • (BUG FIX) Changing/Loading a configuration file did not change the ConfigID
    • (BUG FIX) Tsampler Process – Threshold units incorrect
    • (BUG FIX) Configuration uploads via Ubicom using Panorama 3.1 cause corruption
    • (BUG FIX) User Interface not sleeping on timeouts and excessive amount of requests being sent to the G5

    Version 3.1.5.9 (Released: 2014/12/05)

    • (New Feature) Sensor Extension for Gill Ultrasonic Wind Sensor
    • (New Feature) Sensor Extension for CampBell SR50A Sonic Ranging Sensor (Snow Depth)
    • (Bug Fix) Rain sensor output now returns the set precision value [DL1535]
    • (Bug Fix) Delete Logging Intervals button now fully visible [DL1994]

    Version 3.1.2.11 patch (Released: 2014/09/18)

    • (Enhancement) Now supports Axiom models H1-R, H1-S, H1-RS
    • (Bug Fix) Prevents an “out of memory” condition from occuring

    Version 3.1.1.165 (Released: 2014/09/05)

    • (New Feature) Ability to access G5 transmitter through transparent mode [DL1436]
    • (Enhancement) Improved naming of Threshold Sampling process data points [DL715]
    • (Enhancement) TTS threshold values can now be edited in touchscreen interface [DL456]
    • (Enhancement) Option to not use “-99999” for blank data points [DL1594]
    • (Enhancement) Variable polling duration can now be entered for setting stage offset [DL1686]
    • (Enhancement) Axiom will push configured units to sensor when sensor’s stored units conflict with those configured [DL1705]
    • (Enhancement) Order of variables for Current Conditions output can be now set [DL1763]
    • (Enhancement) Telemetry screen now defaults to Telemetry A tab [DL1802]
    • (Enhancement) Full OS version now displayed in Station Setup [DL1815]
    • (Enhancement) Wake-up delay now user-adjustable [DL1839]
    • (Enhancement) Both raw and offset values now included when using polling feature to set stage offset [DL1915]
    • (Enhancement) Ability to force SDI sensor reading measurement for real-time Current Conditions [DL1918]
    • (Bug Fix) “Not enough disk space” error could occur during update of application software [DL1587]
    • (Bug Fix) Changes to data point names would not carry through to scripts which contained the data points in their name [DL1666]
    • (Bug Fix) RVT power would be cut when entering Telemetry Status screen [DL1712]
    • (Bug Fix) Datalogger crash when inadvertently removing USB memory stick before software update completed [DL1725]
    • (Bug Fix) Minimum/Maximum values at time of occurrence not being logged [DL1740]
    • (Bug Fix) Incorrect logging of Depth Integrated sample and Auxiliary sample prior to Threshold sample taken [DL1412]
    • (Bug Fix) Duration of SDI sensor mapping could be unreasonably long [DL1756]
    • (Bug Fix) Crash when deleting variables from WSC message screen [DL1766]
    • (Bug Fix) Crash when defining a Depth Integrated or Auxiliary sample in the TSampler process [DL1785]
    • (Bug Fix) Weighted Average process would not recover from an error input [DL1812]
    • (Bug Fix) GPS position not recorded regularly, preventing use in calculations [DL1931]
    • (Bug Fix) Incorrect “missing values” placeholder in pseudobinary messages [DL1910]

    Version 3.0.0.71 (2014/03/25)

    • (Enhancement) Option to replace data gaps with ‘-99999’ during CSV download [DL1594]
    • (Enhancement) SDI ports now can use configurable delay to support older SDI sensors [DL1871]

    Version 3.0.0.59 (2014/02/14)

    • (Bug Fix) Random pseudo binary or time-ordered transmissions would occur even when conditions not met [DL1889]
    • (Bug Fix) Behaviour of Change since last logged value corrected to match description on Setup screen [DL1898]
    • (Enhancement) Behaviour of Redundant Data option changed to include data from previous transmissions [DL1890]

    Version 3.0.0.57 (2013/09/06)

    • (Bug Fix) Cumulative Rainfall (RNIN) improperly reset [DL1669, DL1670]
    • (Bug Fix) Low Memory caused a logger reboot [DL1768]
    • (Bug Fix) Error while deleting Transmission parameters [DL1826]
    • (Bug Fix) SDI Command Setup UI Issue [DL1840]

    Version 3.00.49 patch (2013/05/29)

    • (Bug) SDI port remains locked for sensors that don’t issue break sequence after M command [DL1783]

    Version 3.00 (2013/03/26)

    • (New Feature) New icon set makes the Axiom more intuitive, easier to learn and international [DL1434]
    • (New Feature) New Running Peak Calculation Process for Wind Speed [DL1573]
    • (New Feature) Ability to include redundant data in pseudo-binary transmission [DL1650]
    • (Enhancement) Sensor setup added for DigiTemp [DL1218]
    • (Enhancement) Backup con!guration prevents endless power cycle loop [DL1622]
    • (Enhancement) Screen reorganization to Turbidity Threshold Sampling (TSampler) process [DL1661]
    • (Enhancement) Button added to Station Setup screen to clear configuration [DL1662]
    • (Bug Fix) Datalogger crash when editing an AirTalk message that uses a phrase that has been deleted [DL1520]
    • (Bug Fix) Datalogger crash when configuring pseudobinary random message [DL1570]
    • (Bug Fix) Stage offset value for SDI-PT sensor is lost after power cycle of datalogger [DL1665]